Monday, March 11, 2019

Ib Bio Experiment on Effect of Substrate Conc on Enzyme Activity

Practical Assessment 2 The effect of substratum tightfistedness on the prize of enzyme activity of Catalase Aim To investigate the effect of substrate stringency (manipulated by increasing concentration of henry bl from for each one one(prenominal)) on the rate of enzyme activity of catalase, produced by colored cells, on the decomposition of heat content henry atomic number 1 bleach. demonstration Enzymes be biological catalysts that increase the rates of replys.In an enzyme-catalyzed reaction, the substrate binds to the active range and forms enzyme-substrate complex with the enzyme through the lock and chance on method (where the lock represents the enzyme and the key represents the substrate). The enzyme then breaks the bonds in the substrate. The product of the reaction then leaves the enzyme, which hang ins idempotent after the reaction. Without enzymes, many essential processes, such as digestion, would occur besides slowly for life to continue.Catalase is an enzyme produced by our liver-colored cells to break down enthalpy peroxide a common end product of metabolism, but extremely toxic to tissues if accumulated in the body into water and group O. The equation of the reaction is as follows 2 H2O2 O2 + 2 H2O Catalase Catalase In this experiment, we obtain 6% enthalpy peroxide resolving power from a pharmacy and extract live concentrations of catalase from liver cells.Filter musical composition saucers ar dipped into the catalase solution before they are submerged in atomic number 1 peroxide solution. The oxygen produced from the enzyme reaction forget form on the records and cause the disc to be buoyant adequate to drift upwards. We can investigate the effects of substrate concentration on the rate of reaction by catalase by apply different concentrations of heat content peroxide solution, and measuring the rate of reaction by measuring era taken for the disc to float to the surface when sufficient oxygen is pro duced. HypothesisThe scheme for this experiment is that the rate of reaction provide increase with the increase of hydrogen peroxide concentration, if the other factors of enzyme activity (such as temperature, pH and enzyme concentration) are unploughed constant. However, the rate of reaction will stop increasing with hydrogen peroxide concentration at a point where the enzyme concentration becomes a passing factor. At high substrate concentrations, most of the active sites available are occupied since they are saturated with substrate molecules at any give time.Hence, a further increase in substrate concentration will not cause the rate of decomposition of hydrogen peroxide to increase. As such, the expected graph from this experiment is as follows Graph 1 judge graph of rate of reaction against concentration of substance Variables Dependent variable appraise of enzyme activity of catalase in terms of time taken for the magnetic disc to float to the surface of the hydrogen peroxide solution when sufficient oxygen is produced. * Once the stress account disc has reached the bottom of the see render, the stop watch is started.The stopwatch is stopped once the disc has reached the surface of the hydrogen peroxide solution. The recorded clock indicates the amount of time taken for the disk to float to the surface of the hydrogen peroxide solution. Independent variable Concentration of hydrogen peroxide solution. * Add different volumes of water to the different volumes of 6 % hydrogen peroxide solution. Controlled variable(s) 1. Enzyme concentration * We are provided with homogenous liquid liver solution. Hence, the concentration of catalase is constant throughout the liquid liver solution. . Volume of hydrogen peroxide solution * The volume of hydrogen peroxide solution in each test tube is 5cm3. Controlling the volume of hydrogen peroxide solutions ensures that the akin amount of hydrogen peroxide molecules (substrates) is available for reaction i n the test tube. 3. Size of test tubes * The test tubes used each time essential be of the kindred size, length and volume. This is to ensure that the distance the filter paper disc has to travel (between the bottom of the test tube to the surface) is the same for each time. 4. Filter paper disc The filter paper discs should be of the same diameter and of the same thickness. This is to ensure that the same amount of oxygen natural gas is required to lift it to the surface each time thereby change us to determine the time taken for it to do so. 5. Temperature * Enzyme activity is impact by temperature. The experiment is carried out in room temperature (25 C), which is assumed to remain constant throughout the duration of the experiment. Apparatus * Digital stop watch, blameless to 0. 01 s * 6 Test tubes (Same size and length) * 6 Test tube holders * Wooden stick * 500 cm3 beaker 6 measuring cylinders Materials * 6 % hydrogen peroxide solution provided by teacher * Homogenous li quid liver solution provided by teacher * 30 Filter paper discs provided by teacher * Distilled water Procedure 1. 0. 75 % hydrogen peroxide solution is prepared by measuring 3. 00 cm3 of 6 % hydrogen peroxide using a measuring cylinder and then diluting it with 21. 00 cm3 of distilled water. 1. 50 %, 3. 00 %, 4. 50 % and 6. 00 % hydrogen peroxide solutions are prepared using the same method with alike volumes of 6 % hydrogen peroxide and water as shown in the prorogue below.Concentration of hydrogen peroxide solution/ %( 0. 02) Volume of 6 % hydrogen peroxide/ cm3( 0. 01) Volume of water added/ cm3( 0. 01) 0. 75% 3. 00 21. 00 1. 50% 6. 00 18. 00 3. 00% 12. 00 12. 00 4. 50% 18. 00 6. 00 6. 00% 24. 00 0. 00 Table 1 Dilution table for preparing different concentrations of hydrogen peroxide solutions The prepared hydrogen peroxide solutions are poured into test tubes. Each test tube should contain 5 cm3 of the solution. The test tubes with their olutions are placed in the test tube holder, labelled with the concentration of hydrogen peroxide solution that they contain. 2. Obtain homogenous liver liquid from teacher and add 8 cm3 of liver liquid into each petri dish to be used in the experiment. (5 petri dishes) 3. A filter paper disc is soaked with liver liquid in each petri dish. 4. A filter paper disc is removed from petri dish and pushed to the bottom of a test tube with 0. 75 % hydrogen peroxide solution using a wooden stick. 5. The stopwatch is started immediately when the filter paper disc touches the bottom of the test tube. . The stop watch is stopped once the filter paper disc reaches the surface. The time taken for the filter paper disc to float to the surface is recorded. 7. Steps 3 6 are iterate a further 5 times, using other new 0. 75 % hydrogen peroxide solutions. 8. The average of the 6 readings for each hydrogen peroxide concentration is calculated and recorded. The rate of reaction is calculated by the succeeding(a) formula Rate of reacti on = 1/Average time taken for filter paper disc to reach the surface of the hydrogen peroxide solution from the bottom 9.Steps 3-7 are repeated with 1. 50 %, 3. 00 %, 4. 50 % and 6. 00 % hydrogen peroxide solutions 6 times each. Data table Timing for each run conducted/s Concentration of Hydrogen Peroxide solution/% 1 2 3 4 5 6 Average timing for each concentration Hydrogen Peroxide solution/s Rate of reaction for each concentration Hydrogen Peroxide solution/s 0. 75% 1. 50% 3. 00% 4. 50% 6. 00%

No comments:

Post a Comment